![](https://ae01.alicdn.com/kf/H0d59e3bc88eb4f8b96263e8ef9c0882b9.jpg)
![](https://ae01.alicdn.com/kf/H208dc26a9f444ffdb4dae7d34912109cP.jpg)
1.Introduction
The 5W ultra-small series module power supply is a small-volume, high-efficiency AC DC power odule supply designed by Shenzhen Hi-Link Electronics Co.,Ltd. It has the advantages of global input voltage range, low temperature rise, low power consumption,high efficiency, high reliability and high safety isolation. It has been widely used in smart home, automation control, communications equipment, instrumentation and other industries.
MODEL | Size (mm) | Output watt (W) | Output voltage (V) | Output current (mA) | Notes |
HLK-5M03 | 38*23*18 | 5 | 3.3 | 1500 |
|
HLK-5M05 |
|
| 5 | 1000 |
|
HLK-5M09 |
|
| 9 | 560 |
|
HLK-5M12 |
|
| 12 | 450 |
|
HLK-5M24 |
|
| 24 | 208 |
|
2. Product features
1. Ultra-thin, ultra-small, smallest volume;
2. Global universal input voltage(90~265Vac)
3. Low power consumption, green environmental protection, no-load loss<0.1W
4. Low ripple, low noise
5. High output short circuit and over-current protection and self recovery
6. High efficiency, high power density
7. Input and output isolation voltage 3000Vac
8. 100% full load aging and testing
9. High reliability, long life design, continuous working time is greater than 100,000 hours;
10. Meet UL, CE requirements; product design to meet EMC and safety testing requirement;
11. Using high-quality environmentally friendly waterproof plastic potting, moisture, vibration, water and dust to meet IP65 standards
12. Economic solutions, cost-effective
13. Work without external circuit
14. 1 year quality guarantee period
3. Environmental conditions
Items | Technical Parameters | Units | Notes |
Working temperature | -25?+60 | ℃ |
|
Storage temperature | -40?+80 | ℃ |
|
Relative humidity | 5?95 | % |
|
Thermal methods | Natural cooling |
|
|
Atmospheric pressure | 80?106 | Kpa |
|
Altitude | ≤2000 | m |
|
Vibration | Vibration coefficient 10~500Hz, 2G10min./1cycle, 60min.each along X,Y,Z axes |
| Meets requirements for secondary road transportation |
4.Input features
Items | Technical Parameters | Units | Notes |
Rated input voltage | 100~240 | Vac |
|
Input voltage range | 85-264 | Vac | Or 70-350Vdc |
The maximum input current | ≤0.2 | A |
|
Input inrush current | ≤10 | A |
|
Input low start | ≤50 | mS |
|
Long-term reliability | MTBF≥100,000 | h |
|
External fuse recommended | 1A / 250Vac or 10Ω wire wound resistance |
| Slow blow |
Note: Tested at room temperature
5.Output features (5V/1000mA)
Items | Technical Parameters | Units | Notes |
No-load rated output voltage | 5.0±0.1 | Vdc |
|
Full load rated output voltage | 5.0±0.2 | Vdc |
|
Short-time maximum output current | ≥1200 | mA |
|
Long time maximum output current | 1000 | mA |
|
Voltage regulation | ±0.2 | % |
|
Load regulation | ±0.5 | % |
|
Input low voltage efficiency | Vin=115Vac,Output full load≥69 | % |
|
Input high voltage efficiency | Vin=230Vac,Output full load≥70 | % |
|
Output ripple and noise(mVp-p) | ≤50 Rated input voltage, full output load. Using 20MHz bandwidth oscilloscope,
Load side test with 10uF and 0.1uF capacitors | mV |
|
Switching on/off overshoot amplitude | (Rated input voltage, output plus 10% load)≤5 | %VO |
|
Output over-current protection | Output maximum load110-150% | A |
|
Output short circuit protection | Direct short circuit in normal output and automatic return to normal operation after removal of short circuit |
| No damage to the whole device |
6.Input voltage and load characteristics
![](https://ae01.alicdn.com/kf/H8a018aa7d7d5466f8127c2150786a941f.png)