Technical parameter:
Rated Voltage: 8-36VDC
Rated Current: 10A
Working frequency: RF433 frequency
Remote control distance: 50 meters(No occlusion)
Control Mode: Inching mode(default)/interlock mode. user can change the mode by pairing learning operation.
Connection method:
CCW Limit Switch: Connect to the forward limit switch
CW Limit Switch: Connect to the reverse limit switch
CCW Manual Switch: Connect to the manual forward switch
CW Manual Switch: Connect to manual reverse switch
Control mode
1.Inching Mode(default): Press and hold the remote control ▲ button, the motor will rotate forward, and the motor will stop when released.
Press and hold the remote control ▼ button, the motor reverses, and the motor will stop after releasing it.
2.Interlock Mode: Press the remote control ▲ button once, the motor will rotate forward, press the remote control ■ button again, the motor will stop, press the remote control ▼ button once to reverse the motor, and press the remote control ■ button again to stop the motor.
How to change to Interlock Mode:
Interlock Mode: Press the learning button on the controller twice continuously, the learning indicator will flash, and then press the remote control ▲ button, the learning indicator flashes three times and then lights up, press the remote control ■ button, the learning indicator flashes lights up after three times, press the remote control ▼ button, the learning indicator flashes three times and then goes out, the learning is successful.