1. Power supply voltage: DC12V (± 5%)
2. Constant current discharge current adjustment range: 0-10A
Original IR power tube, manufacturer-customized double NMB ball bearing high speed fan, with temperature control stepless speed change function, with industrial large tooth radiator, not afraid of dust, can ensure long-term operation stability (industrial design rejects the use of cheap CPU radiator) Power redundancy is not less than 50% (25 ° C). Classic digital tube display, intuitive and durable (higher temperature resistance than LCD, almost not bad). All 100% power leaves the factory after aging. It is very suitable for assembling the automatic aging cabinet of the power adapter. Welcome to order
Working mode: single mode constant current (CC)
Maximum error of discharge current: 0.7% -0.01A
Maximum error of capacity test: 0.5A 2.5%, 2A 1.5%, 5A and above 1.2%
Maximum power: 100W
*Connect the 12V working power supply to power on and enter the electronic load mode. Make sure that it is in the stopped state (the knob is counterclockwise minimum). Connect the power supply under test to the test input power port. Be careful not to connect the wrong polarity
*Set the constant current through the knob
Note: Because it is open, there is no voltage limit and power limit inside, but normal work should be below 100V and below 100W